Superb quality and spec AB-Com PULSe 4K SE. Crazy offer! Only £129! FREE UK DELIVERY! 4K UHD, Enigma 2, Multiboot 4 images & more!...
Superb quality and spec AB-Com PULSe 4K Rev II Twin Satellite tuner only £179! FREE UK DELIVERY! 4K UHD, Enigma 2, SATA HDD facility, Multiboot 4 images & more!...

[VU+ Duo] hangs on starting after update

philsat

Forum Supporter ,
Joined
Sep 8, 2010
Messages
53
Reaction score
2
Points
0
Did a software update today and when box restarts it hangs on "starting"
Have tried reloading image 3 times and it does the same each time after update.

ta

phil
 
Same thing happened to me. Tried an online update from VIX menu, it hung with the 'wait for your system to restart message on screen' Left it about 20 minutes and then switched off. When I switched it back on, my bouquets were changed. No dramas, just restored from a backup and back in business.

So, all good, just thought I'd mention it here on forum in case it helps the build.
 
Did a software update today and when box restarts it hangs on "starting"
Have tried reloading image 3 times and it does the same each time after update.

ta

phil

What version were you updating from ? as the older 2.3 image with the 2.6 kernel can not be updated to the newer 2.3 image with the 3.1.1. kernel via software update, resulting in the symptoms you have described.
 
What version were you updating from ? as the older 2.3 image with the 2.6 kernel can not be updated to the newer 2.3 image with the 3.1.1. kernel via software update, resulting in the symptoms you have described.

Running 2.3 since december.

ta

phil
 
try running the update via a telnet session just to be sure issue the following command while in the telnet session.

opkg update && opkg upgrade
allow this to fully run its course, it could take a few minutes then run the following command
shutdown -r now

The receiver should reboot and that should be it.
 
try running the update via a telnet session just to be sure issue the following command while in the telnet session.


allow this to fully run its course, it could take a few minutes then run the following command


The receiver should reboot and that should be it.

I had the same problem with my duo`s.. and this worked perfectly on all 5 of them..
 
try running the update via a telnet session just to be sure issue the following command while in the telnet session.


allow this to fully run its course, it could take a few minutes then run the following command


The receiver should reboot and that should be it.


Thats worked OK thanx

ta

phil
 
Hi I also have the same problem.
Can you confirm the upgrade procedure:

I re-install 2.3 from December.
I open a telnet session.
I then use the commands:
opkg update && opkg upgrade
When that is finished shutdown -r now.

Is that all, do I need to do anything else? Do I need to download anything first?
Thanks
 
Hi,
I have answer my own question I just ran the command and it still hangs in shutdown.

There was a message on the telnet window
FATAL:
Module rt2800usb not found
 
The sequence I posted above is just a means of performing a update via a telnet session as opposed to using the blue button > ViX > software update method.
 

OpenViX Feeds Status

Back
Top